<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: Schema automatizare nr. 1b in circuit analog</title>
	<atom:link href="http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/feed/" rel="self" type="application/rss+xml" />
	<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/</link>
	<description>Diorama de la Slobozia - lucrarile mele de modelism feroviar si auto</description>
	<lastBuildDate>Tue, 22 May 2012 17:26:57 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: Bohm Rudolf</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-667</link>
		<dc:creator>Bohm Rudolf</dc:creator>
		<pubDate>Tue, 22 Mar 2011 08:01:08 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-667</guid>
		<description>Nu am legat macazele de contact reed. Ele sunt montate pe releu dar exact unde primeste comanda si de la contact reed. Releul este dotat cu doua cu doua parti de comanda automatizare , eventual o sa-l leg in parea a doua cu semafoarele. O parte ramane pentru curentul de actionare la oprire pornire in gara.</description>
		<content:encoded><![CDATA[<p>Nu am legat macazele de contact reed. Ele sunt montate pe releu dar exact unde primeste comanda si de la contact reed. Releul este dotat cu doua cu doua parti de comanda automatizare , eventual o sa-l leg in parea a doua cu semafoarele. O parte ramane pentru curentul de actionare la oprire pornire in gara.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Bohm Rudolf</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-666</link>
		<dc:creator>Bohm Rudolf</dc:creator>
		<pubDate>Tue, 22 Mar 2011 06:43:08 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-666</guid>
		<description>Am vazut in schemele dumneavoastra mai multe contact reeduri una dupa alta in gara . Pentru fiecare releu sau macaz trebuie separat un contact reed ??? Asta ar fii problema principala oare!!??? Nu rezista contact reedul la mai multi consumanti deodata , de exemplu : un releu si dou macaze . Este necesar pentru fiecare cate un contact reed ???</description>
		<content:encoded><![CDATA[<p>Am vazut in schemele dumneavoastra mai multe contact reeduri una dupa alta in gara . Pentru fiecare releu sau macaz trebuie separat un contact reed ??? Asta ar fii problema principala oare!!??? Nu rezista contact reedul la mai multi consumanti deodata , de exemplu : un releu si dou macaze . Este necesar pentru fiecare cate un contact reed ???</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Bohm Rudolf</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-665</link>
		<dc:creator>Bohm Rudolf</dc:creator>
		<pubDate>Tue, 22 Mar 2011 06:15:36 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-665</guid>
		<description>Buna ziua , as avea nevoie de ajutor in privinta contactelor magnetice !!!  Am instalat contact reeduri de 10 W ,DC 200V , 0,5 A -MK67B , au ars si au facut contact continuu. Am instalat contact reeduri de 50 W , DC 250V/AC 250V , max. 0,5 A - KSK 1A 52-2030 , a ars si a facut contact continuu . Am instalat condensatoare de protectie contra flamei de contact de WiMA 0,1 , 250-AO , au ars si au facut contact continu si asa. Mi sa ars intre timp si doua macaze din cauza contactului continuu , pentru ca dau comanda in acelesi timp la un releu , si doua macaze. Nu stiu ce sa mai fac !!!??? Sunt chiar disperat !!!?? Am controlat sistemul si nu am scurt pe nici unde . Sa fie prea mare amperajul de la transformatorul de 16 V (1,5 A) ???????? Ajutati-ma va rog frumos cu o idee . Eventual sa montez transversal contact reedul in loc de longitudinal ??? Am vazut o schema originala de montare de la ROCO si acolo era montat transversal nu longitudinal !!! Sa fie oare problema asta , sau un alt condensator de protectie contra flamei prea mari (tipul de condensator ??)??? Va rog ajutati-ma daca se poate cu o idee.</description>
		<content:encoded><![CDATA[<p>Buna ziua , as avea nevoie de ajutor in privinta contactelor magnetice !!!  Am instalat contact reeduri de 10 W ,DC 200V , 0,5 A -MK67B , au ars si au facut contact continuu. Am instalat contact reeduri de 50 W , DC 250V/AC 250V , max. 0,5 A &#8211; KSK 1A 52-2030 , a ars si a facut contact continuu . Am instalat condensatoare de protectie contra flamei de contact de WiMA 0,1 , 250-AO , au ars si au facut contact continu si asa. Mi sa ars intre timp si doua macaze din cauza contactului continuu , pentru ca dau comanda in acelesi timp la un releu , si doua macaze. Nu stiu ce sa mai fac !!!??? Sunt chiar disperat !!!?? Am controlat sistemul si nu am scurt pe nici unde . Sa fie prea mare amperajul de la transformatorul de 16 V (1,5 A) ???????? Ajutati-ma va rog frumos cu o idee . Eventual sa montez transversal contact reedul in loc de longitudinal ??? Am vazut o schema originala de montare de la ROCO si acolo era montat transversal nu longitudinal !!! Sa fie oare problema asta , sau un alt condensator de protectie contra flamei prea mari (tipul de condensator ??)??? Va rog ajutati-ma daca se poate cu o idee.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Prognosis</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-593</link>
		<dc:creator>Prognosis</dc:creator>
		<pubDate>Tue, 15 Feb 2011 11:14:13 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-593</guid>
		<description>Intre magnetul de sub lokomotiva si senzor eu am cam 3 mm. Totul depinde si de puterea magnetilor. Eu am scos magneti din unitati optice dar in ultima vreme au aparut in comert magneti puternici, subtiri de 1 mm si foarte mici.</description>
		<content:encoded><![CDATA[<p>Intre magnetul de sub lokomotiva si senzor eu am cam 3 mm. Totul depinde si de puterea magnetilor. Eu am scos magneti din unitati optice dar in ultima vreme au aparut in comert magneti puternici, subtiri de 1 mm si foarte mici.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Prognosis</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-592</link>
		<dc:creator>Prognosis</dc:creator>
		<pubDate>Tue, 15 Feb 2011 11:12:18 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-592</guid>
		<description>Scuze pentru dereglarea linkului la poze, care erau destul de explicite. Am decupat traversele si am montat reed-ul la nivelul traverselor, in unele locuri, in altele am pus releul reed chiar deasupra traverselor. Firele trec prin gauri mici ale suprafetei dioramei, sub ea, unde se leaga la circuit...
Intre magnetul de sub lokomotiva si senzor eu am cam 3 mm. Totul depinde si de puterea magnetilor. Eu am scos magneti din unitati optice dar in ultima vreme au aparut in comert magneti puternici, subtiri de 1 mm si foarte mici.

Vezi mai multe poze la Bariera:
http://trenulete.info/bariera-integrala-home-made-refacere/</description>
		<content:encoded><![CDATA[<p>Scuze pentru dereglarea linkului la poze, care erau destul de explicite. Am decupat traversele si am montat reed-ul la nivelul traverselor, in unele locuri, in altele am pus releul reed chiar deasupra traverselor. Firele trec prin gauri mici ale suprafetei dioramei, sub ea, unde se leaga la circuit&#8230;<br />
Intre magnetul de sub lokomotiva si senzor eu am cam 3 mm. Totul depinde si de puterea magnetilor. Eu am scos magneti din unitati optice dar in ultima vreme au aparut in comert magneti puternici, subtiri de 1 mm si foarte mici.</p>
<p>Vezi mai multe poze la Bariera:<br />
<a href="http://trenulete.info/bariera-integrala-home-made-refacere/" rel="nofollow">http://trenulete.info/bariera-integrala-home-made-refacere/</a></p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Bohm Rudolf</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-591</link>
		<dc:creator>Bohm Rudolf</dc:creator>
		<pubDate>Tue, 15 Feb 2011 10:29:50 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-591</guid>
		<description>Multumesc pentru informatii , as avea inca o intrebare , cum ati montat acest senzor reed ??? peste linie aplicata sau sub linie prin gaurirea blatului dioramei ??? Magnetul respectiv la ce distanta trece de acest senzor , este loc intre linie+senzor si magnet+locomotiva ???
Va multumesc.</description>
		<content:encoded><![CDATA[<p>Multumesc pentru informatii , as avea inca o intrebare , cum ati montat acest senzor reed ??? peste linie aplicata sau sub linie prin gaurirea blatului dioramei ??? Magnetul respectiv la ce distanta trece de acest senzor , este loc intre linie+senzor si magnet+locomotiva ???<br />
Va multumesc.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Prognosis</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-588</link>
		<dc:creator>Prognosis</dc:creator>
		<pubDate>Sun, 13 Feb 2011 07:47:53 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-588</guid>
		<description>In principiu alegeti cele mai mici posibile. Cred ca merge acesta http://conexelectronic.ro/produs.php?id=10219
Acum nu mai vad exact modelul pe care l-am luat eu acum 3 ani...</description>
		<content:encoded><![CDATA[<p>In principiu alegeti cele mai mici posibile. Cred ca merge acesta <a href="http://conexelectronic.ro/produs.php?id=10219" rel="nofollow">http://conexelectronic.ro/produs.php?id=10219</a><br />
Acum nu mai vad exact modelul pe care l-am luat eu acum 3 ani&#8230;</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Bohm Rudolf</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-587</link>
		<dc:creator>Bohm Rudolf</dc:creator>
		<pubDate>Sun, 13 Feb 2011 07:41:59 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-587</guid>
		<description>Daca ma puteti ajuta ??? Care tip de contact magnetic folositi de la firma conexelectronic SRL , as dori sa fac si eu automatizarea la dioramea mea . Exact modelul m-ar interesa , sa stiu ce sa comand. Bohm Rudolf. Va multuesc. Astept un raspuns ,pe cat posibil cat mai urgent.</description>
		<content:encoded><![CDATA[<p>Daca ma puteti ajuta ??? Care tip de contact magnetic folositi de la firma conexelectronic SRL , as dori sa fac si eu automatizarea la dioramea mea . Exact modelul m-ar interesa , sa stiu ce sa comand. Bohm Rudolf. Va multuesc. Astept un raspuns ,pe cat posibil cat mai urgent.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Ordis</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-441</link>
		<dc:creator>Ordis</dc:creator>
		<pubDate>Tue, 12 Oct 2010 14:57:49 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-441</guid>
		<description>Buna schema</description>
		<content:encoded><![CDATA[<p>Buna schema</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Prognosis</title>
		<link>http://trenulete.info/schema-automatizare-nr-1b-in-circuit-analog/comment-page-1/#comment-153</link>
		<dc:creator>Prognosis</dc:creator>
		<pubDate>Wed, 16 Dec 2009 10:29:35 +0000</pubDate>
		<guid isPermaLink="false">http://bestinformer.org/?p=293#comment-153</guid>
		<description>Timpul este dat de condensator releul fiind unul obisnuit. Am fixat acest timp prin tatonari in functie de locul unde este semaforul si de lungimea liniei ce trebuie depasita la plecare.</description>
		<content:encoded><![CDATA[<p>Timpul este dat de condensator releul fiind unul obisnuit. Am fixat acest timp prin tatonari in functie de locul unde este semaforul si de lungimea liniei ce trebuie depasita la plecare.</p>
]]></content:encoded>
	</item>
</channel>
</rss>

